Racor LG 100 Fuel/ Air Seperator
DESCRIPTION | ATTRIBUTE VALUE |
PRODUCT TYPE | FILTER ENGINE AIR |
DESCRIPTION | 3 Stage Fuel/Air Separator |
MAXIMUM FLOW RATE | 17 CFPM (8.0 LPS) |
MAXIMUM HP | N/A |
PORT/CONNECTION SIZE | Inlet/Outlet 5/8″ Hose Barb |
ADDITIONAL DETAIL | UL Listed |
TRADE/BRAND NAME | Racor |
USCG and other regulations prohibit the discharge of fuel and violators could face civil and criminal penalties. When the Racor LG 100 is installed in the fuel tank vent line, the Fuel/Air Separator efficiently separates air from fuel forced into the line. Air is vented, and fuel is returned to the tank. The Fuel/Air Separator captures fuel normally discharged due to agitation and thermal expansion (up to 2.4 PSI). It also eliminates damage to expensive striping and labels and protects finishes from fuel stains.Hose barb: 5/8″.
Stage One – Venting tank fuel is deflected by the flow diverter and fuel is directed down to the drain ports. Air is allowed to bypass and continues out.
Stage Two – Fuel de-foams through a fine wire mesh screen which filters out large
contaminants. Under the screen, the fuel collects temporarily until it can flow back down to the fuel tank.
Stage Three – Vapor collects on the interior surfaces and coalesces. The fuel returns downward by gravity and air continues out. The safety relief valve includes a floating check ball which will not permit a large in-rush of fuel to bypass. In the event of internal pressure reaching 2.4 PSI (0.17 bar), the spring will compress and open the safety seat.

Description found on Racor-Parker website. Click here to be directed to this products page.